How to do a good job of moisture-proof flooring during the Meiyu period

The annual Jiangnan Meiyu season has arrived, and all-pervasive moisture has a great impact on solid wood flooring in home building products. If not properly handled, the wooden floor will be moldy and deformed, cracks, crevices, arches, concaves, mildew, etc., which both cause life troubles and reduce the service life of the floor. Remind the broad masses of people and friends that we must fight for the defense against moisture in the rainy season in the rainy season. The following aspects deserve attention:

Brand shop: solid wood flooring

First, the decoration time choice: Meiyu decoration during the occupants, the best choice for 7 days or so are sunny and then install, the ground humidity should be controlled at about 20, or the ground will evaporate the excessive moisture will lead to increased humidity on the wooden floor.

Second, pay attention to construction and maintenance: moisture during the rain is not easy to volatilize, so we must pay attention to the construction of concealed works during the renovation process to prevent accidents such as water leakage, at the same time, frequent typhoons during this period, pay attention to close the doors and windows, in the maintenance can not be Use a damp cloth to scrub the floor to avoid overheating the wooden floor and affecting its service life or irreversible situation.

Third, the environmental control: try to keep the indoor air humidity balance, otherwise it will lead to rapid expansion or contraction of solid wood flooring, general indoor air humidity of 45-65 is the best state, it is recommended to close the windward direction of the doors and windows to reduce the moisture with the wind into the room . The afternoon or evening is relatively dry compared to the morning. At this time, adjusting the indoor air by opening the window can effectively accelerate the evaporation of water.

Fourth, choose a product with moisture barrier function: simply from the moisture resistance, no matter how good the wood than the most common plastic film. The most scientific and direct method is to add a floor mat between the floor and the ground. In the back of solid wood flooring, a layer of metal-plated polymer aluminum film is applied at normal temperature and cold pressure technology to prevent mold, moisture, insects, and noise. It is environmentally friendly and non-toxic, and has the dual functions of moisture resistance and balance.

Fifth, the rational choice: the quality of wood itself is the key to the moisture resistance of wood flooring! There is a strict national standard for the water-absorption thickness expansion rate of wood floors. It is recommended that consumers choose the best brands and guarantee manufacturers to maximize your home life.

Del floor nature floor interior decoration window

Monarch Control System

NICE Series - an Integrated Solution for Elevators & Escalators

Monarch's Integrated Solution combines control intelligence & inverter drive in one compact package.
An innovative solution for OEM`s who value reliable state of the art performance at a highly competitive cost.
A NICE new comfortable experience from Monarch.

NICE3000+ Elevator High Performance Integrated Controller
Comprehensive Function Features
Direct-To-Floor
By the principles of distance, automatically generate the smooth curves from start of parking, no crawling and directly stop in the levelling position.

Optimum Velocity Profile Efficiency
The elevator controller will optimise the velocity profile based on the desired travel distance demand instead of floor number.

Advanced Door-Opening
Under the automatic operation state, the speed during stopping is less than 0.1 m/s and the gate signals effective, system shorts door-lock signal through advanced door-opening module and then opens the door ahead of time to enhance the elevator efficiency

Category Door Open Holding Set-Time
System can automatically identify different time to keep the open calls to open the door, instructions to open the door, the door to protect open, delay to open the door and to open the door inaccordance with the setting time.

Re-levelling
This may occur when the lift stops at the floor station, and a large number of persons or goods enter or leaves. The levelling fluctuates because of the elastic deformation of elevator Wire Rope and the rubber. System is allowed to run automatically at the relevelling speed to the levelling station with the door open.

Self-Rescue Levelling
The elevator is in its normal operating state, but doesn`t stop at the correct level. If it meets the safety requirements to run, the lift will automatically run slowly to the nearest floor area, and then open the door.

Emergency Inertia Rescue Mode
Applicable for permanent-magnet synchronous motors only. When there is a power failure, system will short-circuit the motor phases through its contactor and produce a restraining torque when in motion. Based on the elevator inertia, the elevator will slide slowly and controller will open the elevator door when it reaches levelling position.

Emergency Self-Rescue Time-Out Protection
When elevator is at balance load or rescue device power capacity is inadequate. Long rescue time lapse is expected and accident may occur. This function enables the system to self-disable the emergency operation.

Elevator Position Auto Calibration
Each time the elevator enters the terminal floor zone, system will self-calibrate the position counter with respect to the 1st slowdown limit switch so that elevator over travel operation will be eliminated.

Fire Alarm Rescue Function
Enable user to preset the elevator designated homing floor when fireman mode is enabled

Monarch Control System,Lift Control System,Elevator Card Access System,Destination Control System