Intelligent relay protection tester This instrument can test a variety of AC and DC current, voltage, signal, reclosing, differential and other single relays and the entire set of relay protection screen, can test the various relays pull-in voltage (current) Values, release voltage (current) values, pull-in and break-off times for various contacts (normally open, normally closed, changeover, delay) are automatically tested three times, the mean is calculated three times automatically, and the test results can be printed.
List of equipment 1, a smart relay protection tester;
2, a set of test lines;
3, fuse two groups;
4, a user manual;
5, a printer description;
6, a product certification.
Technical characteristics:
1. Input power: AC220V±10%50Hz
2. Nominal capacity: 0.75KVA (can increase or decrease capacity as required)
3. Output:
The main circuit: AC0 ~ 250V (3A) (large knob adjustment) 0 ~ 500mA (15V)
Series resistance: 0 to 10A (15V)
Series resistance: 0 ~ 100A (10A)
DC0~350V(3A)
0~500mA(15V)
Series resistance: 0 to 10A (15V)
Secondary circuit: AC0 ~ 20V (1A) (small knob adjustment)
AC0~250V(1A)
DC0~350V(1A)
4 measuring range:
Measuring voltage range: 0 ~ 500.0V (direct measurement)
Measuring AC current range: 0 ~ 500mA (direct measurement)
0 to 10.00A (sensor input)
0 to 100.0A (sensor input)
DC measurement current range: 0 ~ 500.0mA (direct measurement)
0 to 10.00A (splitter input)
Measuring time range: 0 ~ 999..999S (resolution of 1mS)
5. Standard degree: The measurement standard is 0.5 class 6. Dimensions: 272mm×172mm×262mm
7. Weight: 10Kg
Operation key description:
1. Print: After the test is finished, use this key to print the test data. Repeatedly print multiple times.
2. Time measurement: When the voltage (current) is adjusted to the rated value, press this key to automatically measure the relay pull-off time three times.
3. Measured value: Automatically test the pull-in and cut-off voltage (current) value of the relay and repeat the test three times.
4, right: cursor to the right.
5, upturn: number plus 1 or up menu.
6, down; digital minus 1 or down to select the menu.
7, standby: used to control the DC current output.
8. Return: Indicates to give up or return to the previous menu.
9. Confirmation: Indicates confirmation or enters the next level menu.
Pipe Wrap Tape System describe
The XUNDA-T400 series is Cold applied tape coating system for corrosion protection of Oil, Gas, Petrochemical, and Waste Water underground or overhead pipelines.
It is a three-ply cold applied tape with stabiliesed polyethylene backing and butyl rubber adhesive layers on both sides.It is also used as inner-layer tape. It shall be applied by hand or with a wrapping machine
The 3Ply tape shall be applied after the Liquid adhesive and before the outer-layer tape by hand or with a wrapping machine
2 Structure
The specification of the tape consists of four layers,
Internal Adhesive layer:Butyl rubber
External Adhesive layer: Butyl rubber
Film backing:Special blend of stabilized polyethylene fines
Interleaf:Anti adhesive Film Treated with Silicone
3 Features:
Excellent bonding between adhesive and carrier film via co-extruded intermediate layer.
Mechanically highly resistant tape system.
Practically impermeable to water vapour and oxygen.
Resistant to soil bacterial and soil electrolyte.
Compatible with coating from PE,PP,FBE,PU,CTE and Bitumen and ext- .
A Total Coating System with:
High adhesion and shear resistance
Resistance to corrosion disbondment
High electrical resistance
High dielectric strength
High corrosion protection for steel substrates
4 Physical Properties
Thickness: 0.80 mm ( 30 mils)
width: 100 mm to 800 mm
Length: 10 m , 25 m , 30 m and so on
Heavy Duty Double Sided Tape, Strong Double Sided Tape, Removable Double Sided Tape, Wide Double Sided Tape
Jining Xunda Pipe Coating Materials Co.,Ltd , http://www.pipe-wrap.com